Hewlett Packard 10700A 33% Splitter

This item is an HP 10700A 33% Beam Splitter. It is a basic component of the Hewlett Packard Laser Interferometry Distance Measuring Apparatus. It is one of several components based on a 1� steel cube. The cube has a beam-splitting reflector set at 45-degrees and face-centered to three adjacent faces. The mirror surface is coated. These components are useful when it is desired to have three axes tied to a single laser (each axis will require its own interferometer and detector, however). The first beam-splitter in the system would be the 33% splitter, leaving roughly 66% of the beam to travel to a second 50% beam-splitter for the other two axes. In that manner each receiver will be working at approximately the same power level.
, 2nd Grade
The angle of the beam-splitter is not critically set within the cube in order to keep component prices reasonable. For precise positioning it is recommended that the beam-splitter is fixtured using a small leveling base (HP 10710A). These mounts allow for corrections in two directions. Pitch may be adjusted through several degrees about the axis of the mirror component by resetting the cradle position in the base, and yaw may be adjusted using the play in the elongated slots for securing the base. The base of the mount has an open aperture so the beam path may be directed through the base of the fixture. Beams should ONLY be deflected at right angles in each laser / detector assembly in order to avoid depolarization of the laser beams. Beams can be deflected through an aperture in the base of the mount for utmost versatility.

These components have been removed from various fixtures. They meet our requirements for second quality used interferometer components. All optical surfaces are free of serious blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear in very fine condition, although not new. Unlike new components, no hardware is included.

***MPN HP 10700A
***OEM Hewlett Packard ( HP ) / Agilent
***SKU*** DP058

Read More

Hewlett Packard 10700A 33% Splitter, 1st Grade

This item is an HP 10700A 33% Beam Splitter. It is a basic component of the Hewlett Packard Laser Interferometry Distance Measuring Apparatus. It is one of several components based on a 1� steel cube. The cube has a beam-splitting reflector set at 45-degrees and face-centered to three adjacent faces. The mirror surface is coated. These components are useful when it is desired to have three axes tied to a single laser (each axis will require its own interferometer and detector, however). The first beam-splitter in the system would be the 33% splitter, leaving roughly 66% of the beam to travel to a second 50% beam-splitter for the other two axes. In that manner each receiver will be working at approximately the same power level.

The angle of the beam-splitter is not critically set within the cube in order to keep component prices reasonable. For precise positioning it is recommended that the beam-splitter is fixtured using a small leveling base (HP 10710A). These mounts allow for corrections in two directions. Pitch may be adjusted through several degrees about the axis of the mirror component by resetting the cradle position in the base, and yaw may be adjusted using the play in the elongated slots for securing the base. The base of the mount has an open aperture so the beam path may be directed through the base of the fixture. Beams should ONLY be deflected at right angles in each laser / detector assembly in order to avoid depolarization of the laser beams. Beams can be deflected through an aperture in the base of the mount for utmost versatility.

These components have been removed from various fixtures. They meet our requirements for first quality used interferometer components. All optical surfaces are free of blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear only lightly used, if not new. Unlike new components, however, no hardware is included.

***MPN HP 10700A
***OEM Hewlett Packard ( HP ) / Agilent
***SKU*** DP057

Read More

Hewlett Packard 10701A 50% Splitter

This item is an HP 10701A 50% Beam Splitter. It is a basic component of the Hewlett Packard Laser Interferometry Distance Measuring Apparatus. It is one of several components based on a 1� steel cube. The cube has a beam-splitting reflector set at 45-degrees and face-centered to three adjacent faces. The mirror surface is coated. These components are useful when it is desired to have two axes tied to a single laser (each axis will require its own interferometer and detector, however).

The angle of the beam-splitter is not critically set within the cube in order to keep component prices reasonable. For precise positioning it is recommended that the beam-splitter is fixtured using a small leveling base (HP 10710A). These mounts allow for corrections in two directions. Pitch may be adjusted through several degrees about the axis of the mirror component by resetting the cradle position in the base, and yaw may be adjusted using the play in the elongated slots for securing the base. The base of the mount has an open aperture so the beam path may be directed through the base of the fixture. Beams should ONLY be deflected at right angles in each laser / detector assembly in order to avoid depolarization of the laser beams. Beams can be deflected through an aperture in the base of the mount for utmost versatility.

These components have been removed from various fixtures. They meet our requirements for second quality used interferometer components. All optical surfaces are free of serious blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear in very fine condition, although not new. Unlike new components, no hardware is included.

***MPN HP 10701A
***OEM Hewlett Packard ( HP ) / Agilent
***SKU*** DP056

Read More

Hewlett Packard 10701A 50% Splitter,

This item is an HP 10701A 50% Beam Splitter .It is a basic component of the Hewlett Packard Laser Interferometry Distance Measuring Apparatus. It is one of several components based on a 1� steel cube. The cube has a beam-splitting reflector set at 45-degrees and face-centered to three adjacent faces. The mirror surface is coated. These components are useful when it is desired to have two axes tied to a single laser (each axis will require its own interferometer and detector, however).

The angle of the beam-splitter is not critically set within the cube in order to keep component prices reasonable. For precise positioning it is recommended that the beam-splitter is fixtured using a small leveling base (HP 10710A). These mounts allow for corrections in two directions. Pitch may be adjusted through several degrees about the axis of the mirror component by resetting the cradle position in the base, and yaw may be adjusted using the play in the elongated slots for securing the base. The base of the mount has an open aperture so the beam path may be directed through the base of the fixture. Beams should ONLY be deflected at right angles in each laser / detector assembly in order to avoid depolarization of the laser beams. Beams can be deflected through an aperture in the base of the mount for utmost versatility..
These components have been removed from various fixtures. They meet our requirements for first quality used interferometer components. All optical surfaces are free of blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear only lightly used, if not new. Unlike new components, however, no hardware is included.

***MPN HP 10701A
***OEM Hewlett Packard ( HP ) / Agilent
***SKU*** DP055

Read More

Hewlett Packard 10707A Beam Bender

This item is an HP 10707A Beam Bender.It is a basic component of the Hewlett Packard Laser Interferometry Distance Measuring Apparatus. It is one of several components based on a 1� steel cube. The cube has a fully-reflecting 45-degree mirror face-centered to two adjacent faces. The mirror surface is coated…

The angle of the mirror is not critically set within the cube in order to keep component prices reasonable. For precise positioning it is recommended that the beam bender is fixtured using a small leveling base (HP 10710A). These mounts allow for corrections in two directions. Pitch may be adjusted through several degrees about the axis of the mirror component by resetting the cradle position in the base, and yaw may be adjusted using the play in the elongated slots for securing the base. The base of the mount has an open aperture so the beam path may be directed through the base of the fixture. Beams should ONLY be deflected at right angles in each laser / detector assembly in order to avoid depolarization of the laser beams. Beams can be deflected through an aperture in the base of the mount for utmost versatility.

These components have been removed from various fixtures. They meet our requirements for second quality used interferometer components. All optical surfaces are free of serious blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear in very fine condition, although not new. Unlike new components, no hardware is included.

2nd Grade

BMI Surplus, Inc. is your #1 resource for new, pre-owned, recycled, refurbished & used optics, optical tables, laser tables, vibration isolation systems, legs and bases & optical support & optical accessories. We will work with you individually to find the perfect set up for your application. Shop our Optical Tables for the most competitive optical table price. Buy online or give us a call at 781-871-8868.We have experienced customer service representatives standing by ready to help you!
**Shipping, Handling & Freight fees are dependent on your location. We will provide a freight quote to meet your individual needs and work with you if you prefer to use your own carrier. We have 30 years of experience shipping sensitive scientific instruments & industrial equipment!
***MPN HP 10707A
***OEM Hewlett Packard ( HP ) / Agilent
***SKU*** DP053

Read More

Hewlett Packard 10707A Beam Bender, 1st Grade

This item is an HP 10707A Beam Bender.It is a basic component of the Hewlett Packard Laser Interferometry Distance Measuring Apparatus. It is one of several components based on a 1� steel cube. The cube has a fully-reflecting 45-degree mirror face-centered to two adjacent faces. The mirror surface is coated.

The angle of the mirror is not critically set within the cube in order to keep component prices reasonable. For precise positioning it is recommended that the beam bender is fixtured using a small leveling base (HP 10710A). These mounts allow for corrections in two directions. Pitch may be adjusted through several degrees about the axis of the mirror component by resetting the cradle position in the base, and yaw may be adjusted using the play in the elongated slots for securing the base. The base of the mount has an open aperture so the beam path may be directed through the base of the fixture. Beams should ONLY be deflected at right angles in each laser / detector assembly in order to avoid depolarization of the laser beams. Beams can be deflected through an aperture in the base of the mount for utmost versatility.

These components have been removed from various fixtures. They meet our requirements for first quality used interferometer components. All optical surfaces are free of blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear only lightly used, if not new. Unlike new components, however, no hardware is included.

***MPN HP 10707A
***OEM Hewlett Packard ( HP ) / Agilent
***SKU*** DP052

Read More

Hewlett Packard 10710A Leveling Mount, 1st Grade

This item is a Hewlett Packard HP 10710A Small Leveling Mount. It is used with the smaller reflective components in their Laser Interferometry Distance Measuring Apparatus. The mounts allow for corrections in two directions. Pitch may be adjusted through several degrees about the axis of the mirror component by resetting the cradle position in the base, and yaw may be adjusted using the play in the elongated slots for securing the base. The base of the mount has an open aperture so the beam path may be directed through the base of the fixture.

Dimensions of the base are as follows..

Height = 0.5�

Width = 1.1�

Length = 1.85�

Through-bore in base = 0.5�.

These components have been removed from various fixtures. They meet our requirements for first quality used interferometer components. All mechanical adjustments work smoothly and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear only lightly used, if not new. Unlike new mounts, however, no hardware is included other than the two screws used to secure the cradle to the base.

Location W7-A

Photo set 483
***MPN 10710A
***OEM Hewlett Packard ( HP ) / Agilent
***SKU*** DP050

Read More

Siskiyou 1 in. Kinematic Component Mount – Modified

Siskiyou Component Tilt Tip Kinematic Mirror Mount 1 inch IVM100 – Modified

From the Manufacurer:
Travel, each axis — plus or minus 4 degrees
Minimum controllable motion — 3.8 arc seconds
100 TPI adjustment srews (hex head)
Maximum height –4.07 inches
Height of holder — 3.1 inches (less acutators)
Width — 2 inches
Depth of foot — 1.48 inches
Optic axis height — 1.5 inches (including foot)
1″ optic bore with two nylon-tipped set screws
Siskiyou model number — IVM100
***MPN IVM100
***OEM Siskiyou
***SKU*** 61754

Read More