Leitz NPL Fluotar 20x Microscope Objective for

$475.00

Leitz (marked �Leitz Wetzlar Germany�) microscope objective for metallurgical instruments, of NPL Fluotar correction. NPL objectives are corrected to display a perfectly flat image of up to 20mm in diameter (useable in larger field instruments with some loss of resolution at the margins of the field), while Fluotar objectives represent a very high degree of color correction.

� Magnification: 20x
� Numerical Aperture: 0.45na
� Infinity corrected
� Thread size RMS
� Must be used WITHOUT cover glass
� Leica catalog number: 569 233

The objective was removed from an unused KLA project. There are marks on the front bezel exterior that were left by a protective shroud since removed. The glass is flawless. This was a specially mounted version of the NPL 20x for use on KLA wafer inspection stations. There is no spring-loading for sample / objective protection. As such, the objective is most suitable as a replacement lens for KLA systems, but it may also be used on any Leitz metallurgical vertical illuminator that has an RMS thread. It may also be used on the more recent systems when employing an RMS to 32mm thread adapter.

***MPN 569 233
***OEM Leitz
***SKU*** 19519

1 in stock

MB 39 SKU: 19519 Category:

Description

Leitz (marked �Leitz Wetzlar Germany�) microscope objective for metallurgical instruments, of NPL Fluotar correction. NPL objectives are corrected to display a perfectly flat image of up to 20mm in diameter (useable in larger field instruments with some loss of resolution at the margins of the field), while Fluotar objectives represent a very high degree of color correction.

� Magnification: 20x
� Numerical Aperture: 0.45na
� Infinity corrected
� Thread size RMS
� Must be used WITHOUT cover glass
� Leica catalog number: 569 233

The objective was removed from an unused KLA project. There are marks on the front bezel exterior that were left by a protective shroud since removed. The glass is flawless. This was a specially mounted version of the NPL 20x for use on KLA wafer inspection stations. There is no spring-loading for sample / objective protection. As such, the objective is most suitable as a replacement lens for KLA systems, but it may also be used on any Leitz metallurgical vertical illuminator that has an RMS thread. It may also be used on the more recent systems when employing an RMS to 32mm thread adapter.

***MPN 569 233
***OEM Leitz
***SKU*** 19519

Additional information

Weight 1.1 lbs
Dimensions 4 × 4 × 4 in