Showing 61–80 of 387 results

  • Small Leveling Fixture

    $45.00

    Small Leveling Fixture for laser interferometer.

    We are not sure of the manufacturer of this device, but it is very similar in function and size to the HP 10710A Small Leveling Base. It would be used to fixture components using the 1-inch cube factor. This base differs in several respects, however. Instead of using a cradle with a goniometer type motion, this base is hinged on one side using a spring steel blade. There are a pair of set screws which are then used to tip the plate very precisely. They can, in turn, be secured with a pair of adjacent Allen cap screws. This system would allow much finer control of the pitch of the attached device. Yaw may be adjusted using the ample slots in the base. The degree of pitch available is much smaller than that provided by the 10710A, and the component will not remain �face-centered� as it is adjusted. However, due to the small amount of motion provided, we doubt it is of any consequence. The main advantage in this base is in the degree of control.

    BMI Surplus, Inc. is your #1 resource for new, pre-owned, recycled, refurbished & used optics, optical tables, laser tables, vibration isolation systems, legs and bases & optical support & optical accessories. We will work with you individually to find the perfect set up for your application. Shop our Optical Tables for the most competitive optical table price. Buy online or give us a call at 781-871-8868.We have experienced customer service representatives standing by ready to help you!
    **Shipping, Handling & Freight fees are dependent on your location. We will provide a freight quote to meet your individual needs and work with you if you prefer to use your own carrier. We have 30 years of experience shipping sensitive scientific instruments & industrial equipment!

    Don’t see what you are looking for? Use our orange search box on the top right hand corner of this page to customize your search..

    These components have been removed from various fixtures. They meet our requirements for first quality used interferometer components. All optical surfaces are free of blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear only lightly used, if not new. These bases include a pair of mounting screws along with a pair of elongated plates to cover the slot in the base.

    Location W7-A

    Photo set 518
    ***MPN
    ***OEM Brand Unmarked
    ***SKU*** DP086

    Add to cart
  • Large Leveling Fixture

    $50.00

    Large Leveling Fixture

    We are not sure of the manufacturer of this device, but it is very similar in function and size to the HP 10711A Large Leveling Base. It would be used to fixture components using the 1.5: cube factor.This base differs in several respects, however. Instead of using a cradle with a goniometer type motion, this base is hinged on one side using a spring steel blade. There are a pair of set screws which are then used to tip the plate very precisely. They can, in turn, be secured with a pair of adjacent Allen cap screws. This system would allow much finer control of the pitch of the attached device. Yaw may be adjusted using the ample slots in the base. The degree of pitch available is much smaller than that provided by the 10711A, and the component will not remain �face-centered� as it is adjusted. However, due to the small amount of motion provided, we doubt it is of any consequence. The main advantage in this base is in the degree of control.

    These components have been removed from various fixtures. They meet our requirements for first quality used interferometer components. All optical surfaces are free of blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear only lightly used, if not new. Unlike new components, however, no hardware is included.

    Location W7-A

    Photo set 517.

    BMI Surplus, Inc. is your #1 resource for new, pre-owned, recycled, refurbished & used optics, optical tables, laser tables, vibration isolation systems, legs and bases & optical support & optical accessories. We will work with you individually to find the perfect set up for your application. Shop our Optical Tables for the most competitive optical table price. Buy online or give us a call at 781-871-8868.We have experienced customer service representatives standing by ready to help you!
    **Shipping, Handling & Freight fees are dependent on your location. We will provide a freight quote to meet your individual needs and work with you if you prefer to use your own carrier. We have 30 years of experience shipping sensitive scientific instruments & industrial equipment!

    Don’t see what you are looking for? Use our orange search box on the top right hand corner of this page to customize your search..
    ***MPN
    ***OEM Custom
    ***SKU*** DP085

    Add to cart
  • HP 10710A Leveling Mount (Sm) with 45-

    $50.00

    This is an assembly consisting of an HP 10710A Small Leveling Base on which a 45-degree fully reflecting prism has been cemented. Although the prism could have been used to deflect a beam downwards through the aperture in the base, the excess cement that covers the face of the prism adjacent to the base would preclude such use � much of the aperture is filled with cement. Therefore it was intended for use in directing a beam upwards at right-angles to the base-plate.

    The prisms are very rigidly mounted. Rather than break the prisms in an effort to remove them, we have decided to offer them in the condition found. The first-surface mirror is in excellent condition, and the prisms (although exposed) have not been chipped or damaged.

    Dimensions of the base are as follows.

    Height = 0.5�

    Width = 1.1�

    Length = 1.85�

    Through-bore in base = 0.5�

    Prism face 20mm square

    These components have been removed from various fixtures. They meet our requirements for second quality used interferometer components. All mechanical adjustments work smoothly and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear only lightly used, however I doubt the prisms can be removed without damaging the glass. No hardware is included other than the two screws used to secure the cradle to the base.

    Location W7-A

    Photo set 513
    ***MPN HP 10710A
    ***OEM Hewlett Packard ( HP ) / Agilent
    ***SKU*** DP081

    Add to cart
  • Hewlett Packard 10556A Retroreflector, 1st Grade

    $170.00

    This item is an HP 10556A Retroreflector in the large size (2� square) mounting format found in the earlier Hewlett-Packard Laser Interferometer Distance Measurment Apparatus. There are four countersunk holes in a 1.4� face-centered pattern. The holes are countersunk on both sides of the mounting flange. The �outside� set of countersinks are used when attaching the retroreflector to one of the 105xx series of interferometers. The �inside� set of countersinks are used to secure the corner cube to the special carrier with post (HP part number 10550B).

    These components have been removed from various fixtures. They meet our requirements for first quality used interferometer components. All optical surfaces are free of blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear only lightly used, if not new. Unlike new components, however, no hardware is included. Please note that not all of the reflectors have the plastic sleeve over the cylinder.

    ***MPN HP 10556A
    ***OEM Hewlett Packard ( HP ) / Agilent
    ***SKU*** DP079

    Add to cart
  • Hewlett Packard 10703A Retroreflector, 1st Grade

    $150.00

    This is an HP 10703A Retroreflector. It consists of a glass corner-cube reflector in a cylindrical mount. It is a component in the Hewlett-Packard Laser Interferometer Distance Measurement Apparatus. The reflector is attachable to the 1.5� size interferometer bodies. They may also be fixtured independently of the interferometer.

    These components have been removed from various fixtures. They meet our requirements for first quality used interferometer components. All optical surfaces are free of blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear only lightly used, if not new. Unlike new components, however, no hardware is included. The only cosmetic issue with this reflector is that the original label is missing, hence the slightly reduced price.

    Location W7-A

    Photo set 509
    ***MPN HP 10703A
    ***OEM Hewlett Packard ( HP ) / Agilent
    ***SKU*** DP077

    Add to cart
  • Hewlett Packard 10703A Retroreflector, 1st Grade

    $160.00

    This is an HP 10703A Retroreflector. It consists of a glass corner-cube reflector in a cylindrical mount. It is a component in the Hewlett-Packard Laser Interferometer Distance Measurement Apparatus. The reflector is attachable to the 1.5� size interferometer bodies. They may also be fixtured independently of the interferometer.

    These components have been removed from various fixtures. They meet our requirements for first quality used interferometer components. All optical surfaces are free of blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear only lightly used, if not new. Unlike new components, however, no hardware is included.

    ***MPN HP 10703A
    ***OEM Hewlett Packard ( HP ) / Agilent
    ***SKU*** DP076

    Add to cart
  • Hewlett Packard 10722A Converter Window, 1st

    $155.00

    This is an HP 10722A Plane Mirror Converter window. It consists of a glass wedge that allows mounting a 10702A Linear Interferometer in a fixed position with a retroreflector attached to the moving component of a stage. It is a component in the Hewlett-Packard Laser Interferometer Distance Measurement Apparatus. The window is attachable to the 1.5� size interferometer bodies.

    These components have been removed from various fixtures. They meet our requirements for first quality used interferometer components. All optical surfaces are free of blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear only lightly used, if not new. Unlike new components, however, no hardware is included. The only cosmetic issue with this particular window is the missing HP label with the nomenclature, hence the slightly lower price.

    ***MPN HP 10722A
    ***OEM Hewlett Packard ( HP ) / Agilent
    ***SKU*** DP075

    Add to cart
  • Hewlett Packard 10722A Converter Window, 1st

    $150.00

    This is an HP 10722A Plane Mirror Converter window. It consists of a glass wedge that allows mounting a 10702A Linear Interferometer in a fixed position with a retroreflector attached to the moving component of a stage. It is a component in the Hewlett-Packard Laser Interferometer Distance Measurement Apparatus. The window is attachable to the 1.5� size interferometer bodies.

    These components have been removed from various fixtures. They meet our requirements for first quality used interferometer components. All optical surfaces are free of blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear only lightly used, if not new. Unlike new components, however, no hardware is included.

    ***MPN HP 10722A
    ***OEM Hewlett Packard ( HP ) / Agilent
    ***SKU*** DP074

    Add to cart
  • HP 10702A Linear Interferometer 1st Grade

    $225.00

    This item is an HP 10702A Linear Interferometer with one HP 10703A. Retroreflector and one HP 10722 Converter Window attached. A second reflector is not included. This is the basic interferometer in the 1.5� cube factor. It consists of a polarizing beam-splitter and the corner-cube reflector. One interferometer and one detector are required for each axis in the Hewlett-Packard Laser Interferometer Distance Measurement Apparatus. The addition of the compensating converter window allows a second retroreflector to move relative to the fixed interferometer body..

    The angle of the beam-splitter is not critically set within the cube in order to keep component prices reasonable. For precise positioning it is recommended that the beam-splitter is fixtured using a large leveling base (HP 10711A). These mounts allow for corrections in two directions. Pitch may be adjusted through several degrees about the axis of the mirror component by resetting the cradle position in the base, and yaw may be adjusted using the play in the elongated slots for securing the base. The base of the mount has an open aperture so the beam path may be directed through the base of the fixture.

    These components have been removed from various fixtures. They meet our requirements for first quality used interferometer components. All optical surfaces are free of blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear only lightly used, if not new. Unlike new components, however, no hardware is included.

    ***MPN HP 10702A
    ***OEM Hewlett Packard ( HP ) / Agilent
    ***SKU*** DP073

    Add to cart
  • HP 10702A Linear Interferometer 1st Grade

    $300.00

    This item is an HP 10702A Linear Interferometer with one HP 10703A Retroreflector attached. No converter window or second reflector is included. This is the basic interferometer in the 1.5� cube factor. It consists of a polarizing beam-splitter and the corner-cube reflector. One interferometer and one detector are required for each axis in the Hewlett-Packard Laser Interferometer Distance Measurement Apparatus.

    The angle of the beam-splitter is not critically set within the cube in order to keep component prices reasonable. For precise positioning it is recommended that the beam-splitter is fixtured using a large leveling base (HP 10711A). These mounts allow for corrections in two directions. Pitch may be adjusted through several degrees about the axis of the mirror component by resetting the cradle position in the base, and yaw may be adjusted using the play in the elongated slots for securing the base. The base of the mount has an open aperture so the beam path may be directed through the base of the fixture.

    These components have been removed from various fixtures. They meet our requirements for first quality used interferometer components. All optical surfaces are free of blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear only lightly used, if not new. Unlike new components, however, no hardware is included.

    BMI Surplus, Inc. is your #1 resource for new, pre-owned, recycled, refurbished & used optics, optical tables, laser tables, vibration isolation systems, legs and bases & optical support & optical accessories. We will work with you individually to find the perfect set up for your application. Shop our Optical Tables for the most competitive optical table price. Buy online or give us a call at 781-871-8868.We have experienced customer service representatives standing by ready to help you!
    **Shipping, Handling & Freight fees are dependent on your location. We will provide a freight quote to meet your individual needs and work with you if you prefer to use your own carrier. We have 30 years of experience shipping sensitive scientific instruments & industrial equipment!

    Don’t see what you are looking for? Use our orange search box on the top right hand corner of this page to customize your search..
    ***MPN HP 10702A
    ***OEM Hewlett Packard ( HP ) / Agilent
    ***SKU*** DP072

    Add to cart
  • HP 10715A Differential Interferometer

    $1,200.00

    HP 10715A Differential Interferometer

    HP 10715A Differential Interferometer, new in the original packing. It is one of the more elaborate interferometers using the 1.5� cube form factor. These components belong to the Hewlett-Packard Laser Interferometer Distance Measurement Apparatus. The interferometer includes a special diagonal beam-splitting window which I have not figured out � it may be some sort of phase shifting plate to turn the plane of polarization. The interferometer includes a special magnetic target disk used in the initial setup of the device. It includes two retroreflector modules and a converter window, but attached to the opposite side from the converter, is another module with a right-angle beam-splitter with two exit ports on each side, marked �A� and �B�. There appears to be a quarter-wave plate between the main interferometer body and the second beam splitter. I have no idea how the diagonal mirror is used. . .

    Slight chip on unused portion of the reference mirror.

    Again, this is new in the box. I believe this component would benefit from the use of the large leveling base (HP 10711A). The only mounting faces are the opposite sides of the main interferometer body.

    ***MPN HP 10715A
    ***OEM Hewlett Packard ( HP ) / Agilent
    ***SKU*** DP070

    Add to cart
  • HP 10702A Linear Interferometer Options

    $350.00

    HP 10702A Linear Interferometer with Options 001

    This item, while missing the original HP label, has been identified as a type 10702A Linear Interferometer. The interferometer body has been scribed with the original beam-path schematic diagram found on the original label. This is one of the �medium-sized� components in the Hewlett-Packard Laser Interferometer Distance Measurement Apparatus. The central cube is 1.5� square. On one side of the beam-splitter is a type HP 10703A Retroreflector, and on the opposite side, a type HP 10724A Plane Mirror. This interferometer is equipped with the Option 001 � a type HP 10722 Converter Window. None of the components have the original labels.

    The angle of the beam-splitter is not critically set within the cube in order to keep component prices reasonable. For precise positioning it is recommended that the beam-splitter is fixtured using a large leveling base (HP 10711A). These mounts allow for corrections in two directions. Pitch may be adjusted through several degrees about the axis of the mirror component by resetting the cradle position in the base, and yaw may be adjusted using the play in the elongated slots for securing the base. The base of the mount has an open aperture so the beam path may be directed through the base of the fixture. Beams should ONLY be deflected at right angles in each laser / detector assembly in order to avoid depolarization of the laser beams.

    These components have been removed from various fixtures. They have been classified as second quality because of the missing labels as well as the rather crudely scribed schematics. All optical surfaces are free of blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear in very fine condition, although not new. Unlike new components, no hardware is included.

    BMI Surplus, Inc. is your #1 resource for new, pre-owned, recycled, refurbished & used optics, optical tables, laser tables, vibration isolation systems, legs and bases & optical support & optical accessories. We will work with you individually to find the perfect set up for your application. Shop our Optical Tables for the most competitive optical table price. Buy online or give us a call at 781-871-8868.We have experienced customer service representatives standing by ready to help you!
    **Shipping, Handling & Freight fees are dependent on your location. We will provide a freight quote to meet your individual needs and work with you if you prefer to use your own carrier. We have 30 years of experience shipping sensitive scientific instruments & industrial equipment!

    Don’t see what you are looking for? Use our orange search box on the top right hand corner of this page to customize your search.

    ***MPN HP 10702A
    ***OEM Hewlett Packard ( HP ) / Agilent
    ***SKU*** DP068

    Add to cart
  • Hewlett Packard 10567A Beam Splitter, 1st Grade

    $195.00

    This item is an HP 10567A Dual Beam Beam-Splitter. This is a rather elaborate component in the Hewlett-Packard Laser Interferometry Dimensional Measurement System. It is intended for use with two axis stages. There is a single 45-degree diagonal mirror mounted within the block, but it is not face-centered. The mirror has three �zones� of reflectance (or transmission), and three apertures on the side of the block facing the laser source. The lowest aperture is uncoated so the entire beam passes straight through the block The central aperture is where the source laser enters the block. The substrate at that point has a 50% coating, so half of the energy is reflected to the top on the block, and the remainder passes straight through. The upper aperture (on the side facing the laser) has a 100% mirror � all the light flux is diverted at right angles.

    The outer two apertures on the side facing the laser are intended for the return beams from the interferometer bodies in each axis. The receivers may be placed on the same side of the block as the laser source. This is very useful when there are space constraints.

    These components have been removed from various fixtures. They meet our requirements for first quality used interferometer components. All optical surfaces are free of blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear only lightly used, if not new. Unlike new components, however, no hardware is included.

    ***MPN HP 10567A
    ***OEM Hewlett Packard ( HP ) / Agilent
    ***SKU*** DP064

    Add to cart
  • HP 10565A Remote Interferometer

    $450.00

    This is an HP 10565A Remote Interferometer. It is one of the major components in the Hewlett-Packard Laser Interferometer Measurement System. It is based on the larger 2� cubes, and uses a 1.4� square bolt pattern for mounting. The interferometer includes the matching retroreflector (HP 10556A). The remaining three entry / exit faces of the cube appear to have � lambda plates installed within them. I believe this is the standard configuration for the interferometer. No other reflectors (retro- or mirror) are included.
    These components have been removed from various fixtures. They meet our requirements for first quality used interferometer components. All optical surfaces are free of blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear only lightly used, if not new. Unlike new components, however, no hardware is included.
    BMI Surplus, Inc. is your #1 resource for new, pre-owned, recycled, refurbished & used optics, optical tables, laser tables, vibration isolation systems, legs and bases & optical support & optical accessories. We will work with you individually to find the perfect set up for your application. Shop our Optical Tables for the most competitive optical table price. Buy online or give us a call at 781-871-8868.We have experienced customer service representatives standing by ready to help you!

    ***MPN HP 10565A
    ***OEM Hewlett Packard ( HP ) / Agilent
    ***SKU*** DP063

    Add to cart
  • Hewlett Packard 10557A Turning Mirror, 1st Grade

    $120.00

    This item is an HP 10557A Turning Mirror. It is one of several basic components in the Hewlett-Packard Laser Interferometer Dimensional Measurement System. The components in the 105xx systems are usually based on a 2� cube, as is this device. The mirror is placed at a 45-degree angle, and positioned so it bisects the cube. The only mounting provisions are on the diagonal faces, so the beam can only be turned parallel to the mounting fixture.

    Diameter of the mirror surface is about 1.5�, and the surface is coated. The mounting holes are face-centered based on a 1.4� square. Beams should ONLY be deflected at right angles in each laser / detector assembly in order to avoid depolarization of the laser beams.

    These components have been removed from various fixtures. They meet our requirements for first quality used interferometer components. All optical surfaces are free of blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear only lightly used, if not new. Unlike new components, however, no hardware is included.

    ***MPN HP 10557A
    ***OEM Hewlett Packard ( HP ) / Agilent
    ***SKU*** DP062

    Add to cart
  • Hewlett Packard 10700A 33% Splitter

    $105.00

    This item is an HP 10700A 33% Beam Splitter. It is a basic component of the Hewlett Packard Laser Interferometry Distance Measuring Apparatus. It is one of several components based on a 1� steel cube. The cube has a beam-splitting reflector set at 45-degrees and face-centered to three adjacent faces. The mirror surface is coated. These components are useful when it is desired to have three axes tied to a single laser (each axis will require its own interferometer and detector, however). The first beam-splitter in the system would be the 33% splitter, leaving roughly 66% of the beam to travel to a second 50% beam-splitter for the other two axes. In that manner each receiver will be working at approximately the same power level.
    , 2nd Grade
    The angle of the beam-splitter is not critically set within the cube in order to keep component prices reasonable. For precise positioning it is recommended that the beam-splitter is fixtured using a small leveling base (HP 10710A). These mounts allow for corrections in two directions. Pitch may be adjusted through several degrees about the axis of the mirror component by resetting the cradle position in the base, and yaw may be adjusted using the play in the elongated slots for securing the base. The base of the mount has an open aperture so the beam path may be directed through the base of the fixture. Beams should ONLY be deflected at right angles in each laser / detector assembly in order to avoid depolarization of the laser beams. Beams can be deflected through an aperture in the base of the mount for utmost versatility.

    These components have been removed from various fixtures. They meet our requirements for second quality used interferometer components. All optical surfaces are free of serious blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear in very fine condition, although not new. Unlike new components, no hardware is included.

    ***MPN HP 10700A
    ***OEM Hewlett Packard ( HP ) / Agilent
    ***SKU*** DP058

    Add to cart
  • Hewlett Packard 10700A 33% Splitter, 1st Grade

    $105.00

    This item is an HP 10700A 33% Beam Splitter. It is a basic component of the Hewlett Packard Laser Interferometry Distance Measuring Apparatus. It is one of several components based on a 1� steel cube. The cube has a beam-splitting reflector set at 45-degrees and face-centered to three adjacent faces. The mirror surface is coated. These components are useful when it is desired to have three axes tied to a single laser (each axis will require its own interferometer and detector, however). The first beam-splitter in the system would be the 33% splitter, leaving roughly 66% of the beam to travel to a second 50% beam-splitter for the other two axes. In that manner each receiver will be working at approximately the same power level.

    The angle of the beam-splitter is not critically set within the cube in order to keep component prices reasonable. For precise positioning it is recommended that the beam-splitter is fixtured using a small leveling base (HP 10710A). These mounts allow for corrections in two directions. Pitch may be adjusted through several degrees about the axis of the mirror component by resetting the cradle position in the base, and yaw may be adjusted using the play in the elongated slots for securing the base. The base of the mount has an open aperture so the beam path may be directed through the base of the fixture. Beams should ONLY be deflected at right angles in each laser / detector assembly in order to avoid depolarization of the laser beams. Beams can be deflected through an aperture in the base of the mount for utmost versatility.

    These components have been removed from various fixtures. They meet our requirements for first quality used interferometer components. All optical surfaces are free of blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear only lightly used, if not new. Unlike new components, however, no hardware is included.

    ***MPN HP 10700A
    ***OEM Hewlett Packard ( HP ) / Agilent
    ***SKU*** DP057

    Add to cart
  • Hewlett Packard 10701A 50% Splitter

    $95.00

    This item is an HP 10701A 50% Beam Splitter. It is a basic component of the Hewlett Packard Laser Interferometry Distance Measuring Apparatus. It is one of several components based on a 1� steel cube. The cube has a beam-splitting reflector set at 45-degrees and face-centered to three adjacent faces. The mirror surface is coated. These components are useful when it is desired to have two axes tied to a single laser (each axis will require its own interferometer and detector, however).

    The angle of the beam-splitter is not critically set within the cube in order to keep component prices reasonable. For precise positioning it is recommended that the beam-splitter is fixtured using a small leveling base (HP 10710A). These mounts allow for corrections in two directions. Pitch may be adjusted through several degrees about the axis of the mirror component by resetting the cradle position in the base, and yaw may be adjusted using the play in the elongated slots for securing the base. The base of the mount has an open aperture so the beam path may be directed through the base of the fixture. Beams should ONLY be deflected at right angles in each laser / detector assembly in order to avoid depolarization of the laser beams. Beams can be deflected through an aperture in the base of the mount for utmost versatility.

    These components have been removed from various fixtures. They meet our requirements for second quality used interferometer components. All optical surfaces are free of serious blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear in very fine condition, although not new. Unlike new components, no hardware is included.

    ***MPN HP 10701A
    ***OEM Hewlett Packard ( HP ) / Agilent
    ***SKU*** DP056

    Add to cart
  • Hewlett Packard 10701A 50% Splitter,

    $90.00

    This item is an HP 10701A 50% Beam Splitter .It is a basic component of the Hewlett Packard Laser Interferometry Distance Measuring Apparatus. It is one of several components based on a 1� steel cube. The cube has a beam-splitting reflector set at 45-degrees and face-centered to three adjacent faces. The mirror surface is coated. These components are useful when it is desired to have two axes tied to a single laser (each axis will require its own interferometer and detector, however).

    The angle of the beam-splitter is not critically set within the cube in order to keep component prices reasonable. For precise positioning it is recommended that the beam-splitter is fixtured using a small leveling base (HP 10710A). These mounts allow for corrections in two directions. Pitch may be adjusted through several degrees about the axis of the mirror component by resetting the cradle position in the base, and yaw may be adjusted using the play in the elongated slots for securing the base. The base of the mount has an open aperture so the beam path may be directed through the base of the fixture. Beams should ONLY be deflected at right angles in each laser / detector assembly in order to avoid depolarization of the laser beams. Beams can be deflected through an aperture in the base of the mount for utmost versatility..
    These components have been removed from various fixtures. They meet our requirements for first quality used interferometer components. All optical surfaces are free of blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear only lightly used, if not new. Unlike new components, however, no hardware is included.

    ***MPN HP 10701A
    ***OEM Hewlett Packard ( HP ) / Agilent
    ***SKU*** DP055

    Add to cart
  • Hewlett Packard 10707A Beam Bender

    $70.00

    This item is an HP 10707A Beam Bender.It is a basic component of the Hewlett Packard Laser Interferometry Distance Measuring Apparatus. It is one of several components based on a 1� steel cube. The cube has a fully-reflecting 45-degree mirror face-centered to two adjacent faces. The mirror surface is coated…

    The angle of the mirror is not critically set within the cube in order to keep component prices reasonable. For precise positioning it is recommended that the beam bender is fixtured using a small leveling base (HP 10710A). These mounts allow for corrections in two directions. Pitch may be adjusted through several degrees about the axis of the mirror component by resetting the cradle position in the base, and yaw may be adjusted using the play in the elongated slots for securing the base. The base of the mount has an open aperture so the beam path may be directed through the base of the fixture. Beams should ONLY be deflected at right angles in each laser / detector assembly in order to avoid depolarization of the laser beams. Beams can be deflected through an aperture in the base of the mount for utmost versatility.

    These components have been removed from various fixtures. They meet our requirements for second quality used interferometer components. All optical surfaces are free of serious blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear in very fine condition, although not new. Unlike new components, no hardware is included.

    2nd Grade

    BMI Surplus, Inc. is your #1 resource for new, pre-owned, recycled, refurbished & used optics, optical tables, laser tables, vibration isolation systems, legs and bases & optical support & optical accessories. We will work with you individually to find the perfect set up for your application. Shop our Optical Tables for the most competitive optical table price. Buy online or give us a call at 781-871-8868.We have experienced customer service representatives standing by ready to help you!
    **Shipping, Handling & Freight fees are dependent on your location. We will provide a freight quote to meet your individual needs and work with you if you prefer to use your own carrier. We have 30 years of experience shipping sensitive scientific instruments & industrial equipment!
    ***MPN HP 10707A
    ***OEM Hewlett Packard ( HP ) / Agilent
    ***SKU*** DP053

    Add to cart