HP 10702A Linear Interferometer 1st Grade

This item is an HP 10702A Linear Interferometer with one HP 10703A. Retroreflector and one HP 10722 Converter Window attached. A second reflector is not included. This is the basic interferometer in the 1.5� cube factor. It consists of a polarizing beam-splitter and the corner-cube reflector. One interferometer and one detector are required for each axis in the Hewlett-Packard Laser Interferometer Distance Measurement Apparatus. The addition of the compensating converter window allows a second retroreflector to move relative to the fixed interferometer body..

The angle of the beam-splitter is not critically set within the cube in order to keep component prices reasonable. For precise positioning it is recommended that the beam-splitter is fixtured using a large leveling base (HP 10711A). These mounts allow for corrections in two directions. Pitch may be adjusted through several degrees about the axis of the mirror component by resetting the cradle position in the base, and yaw may be adjusted using the play in the elongated slots for securing the base. The base of the mount has an open aperture so the beam path may be directed through the base of the fixture.

These components have been removed from various fixtures. They meet our requirements for first quality used interferometer components. All optical surfaces are free of blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear only lightly used, if not new. Unlike new components, however, no hardware is included.

***MPN HP 10702A
***OEM Hewlett Packard ( HP ) / Agilent
***SKU*** DP073

Read More

HP 10702A Linear Interferometer 1st Grade

This item is an HP 10702A Linear Interferometer with one HP 10703A Retroreflector attached. No converter window or second reflector is included. This is the basic interferometer in the 1.5� cube factor. It consists of a polarizing beam-splitter and the corner-cube reflector. One interferometer and one detector are required for each axis in the Hewlett-Packard Laser Interferometer Distance Measurement Apparatus.

The angle of the beam-splitter is not critically set within the cube in order to keep component prices reasonable. For precise positioning it is recommended that the beam-splitter is fixtured using a large leveling base (HP 10711A). These mounts allow for corrections in two directions. Pitch may be adjusted through several degrees about the axis of the mirror component by resetting the cradle position in the base, and yaw may be adjusted using the play in the elongated slots for securing the base. The base of the mount has an open aperture so the beam path may be directed through the base of the fixture.

These components have been removed from various fixtures. They meet our requirements for first quality used interferometer components. All optical surfaces are free of blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear only lightly used, if not new. Unlike new components, however, no hardware is included.

BMI Surplus, Inc. is your #1 resource for new, pre-owned, recycled, refurbished & used optics, optical tables, laser tables, vibration isolation systems, legs and bases & optical support & optical accessories. We will work with you individually to find the perfect set up for your application. Shop our Optical Tables for the most competitive optical table price. Buy online or give us a call at 781-871-8868.We have experienced customer service representatives standing by ready to help you!
**Shipping, Handling & Freight fees are dependent on your location. We will provide a freight quote to meet your individual needs and work with you if you prefer to use your own carrier. We have 30 years of experience shipping sensitive scientific instruments & industrial equipment!

Don’t see what you are looking for? Use our orange search box on the top right hand corner of this page to customize your search..
***MPN HP 10702A
***OEM Hewlett Packard ( HP ) / Agilent
***SKU*** DP072

Read More

HP 10715A Differential Interferometer

HP 10715A Differential Interferometer

HP 10715A Differential Interferometer, new in the original packing. It is one of the more elaborate interferometers using the 1.5� cube form factor. These components belong to the Hewlett-Packard Laser Interferometer Distance Measurement Apparatus. The interferometer includes a special diagonal beam-splitting window which I have not figured out � it may be some sort of phase shifting plate to turn the plane of polarization. The interferometer includes a special magnetic target disk used in the initial setup of the device. It includes two retroreflector modules and a converter window, but attached to the opposite side from the converter, is another module with a right-angle beam-splitter with two exit ports on each side, marked �A� and �B�. There appears to be a quarter-wave plate between the main interferometer body and the second beam splitter. I have no idea how the diagonal mirror is used. . .

Slight chip on unused portion of the reference mirror.

Again, this is new in the box. I believe this component would benefit from the use of the large leveling base (HP 10711A). The only mounting faces are the opposite sides of the main interferometer body.

***MPN HP 10715A
***OEM Hewlett Packard ( HP ) / Agilent
***SKU*** DP070

Read More

HP 10702A Linear Interferometer Options

HP 10702A Linear Interferometer with Options 001

This item, while missing the original HP label, has been identified as a type 10702A Linear Interferometer. The interferometer body has been scribed with the original beam-path schematic diagram found on the original label. This is one of the �medium-sized� components in the Hewlett-Packard Laser Interferometer Distance Measurement Apparatus. The central cube is 1.5� square. On one side of the beam-splitter is a type HP 10703A Retroreflector, and on the opposite side, a type HP 10724A Plane Mirror. This interferometer is equipped with the Option 001 � a type HP 10722 Converter Window. None of the components have the original labels.

The angle of the beam-splitter is not critically set within the cube in order to keep component prices reasonable. For precise positioning it is recommended that the beam-splitter is fixtured using a large leveling base (HP 10711A). These mounts allow for corrections in two directions. Pitch may be adjusted through several degrees about the axis of the mirror component by resetting the cradle position in the base, and yaw may be adjusted using the play in the elongated slots for securing the base. The base of the mount has an open aperture so the beam path may be directed through the base of the fixture. Beams should ONLY be deflected at right angles in each laser / detector assembly in order to avoid depolarization of the laser beams.

These components have been removed from various fixtures. They have been classified as second quality because of the missing labels as well as the rather crudely scribed schematics. All optical surfaces are free of blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear in very fine condition, although not new. Unlike new components, no hardware is included.

BMI Surplus, Inc. is your #1 resource for new, pre-owned, recycled, refurbished & used optics, optical tables, laser tables, vibration isolation systems, legs and bases & optical support & optical accessories. We will work with you individually to find the perfect set up for your application. Shop our Optical Tables for the most competitive optical table price. Buy online or give us a call at 781-871-8868.We have experienced customer service representatives standing by ready to help you!
**Shipping, Handling & Freight fees are dependent on your location. We will provide a freight quote to meet your individual needs and work with you if you prefer to use your own carrier. We have 30 years of experience shipping sensitive scientific instruments & industrial equipment!

Don’t see what you are looking for? Use our orange search box on the top right hand corner of this page to customize your search.

***MPN HP 10702A
***OEM Hewlett Packard ( HP ) / Agilent
***SKU*** DP068

Read More

HP 10565A Remote Interferometer

This is an HP 10565A Remote Interferometer. It is one of the major components in the Hewlett-Packard Laser Interferometer Measurement System. It is based on the larger 2� cubes, and uses a 1.4� square bolt pattern for mounting. The interferometer includes the matching retroreflector (HP 10556A). The remaining three entry / exit faces of the cube appear to have � lambda plates installed within them. I believe this is the standard configuration for the interferometer. No other reflectors (retro- or mirror) are included.
These components have been removed from various fixtures. They meet our requirements for first quality used interferometer components. All optical surfaces are free of blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear only lightly used, if not new. Unlike new components, however, no hardware is included.
BMI Surplus, Inc. is your #1 resource for new, pre-owned, recycled, refurbished & used optics, optical tables, laser tables, vibration isolation systems, legs and bases & optical support & optical accessories. We will work with you individually to find the perfect set up for your application. Shop our Optical Tables for the most competitive optical table price. Buy online or give us a call at 781-871-8868.We have experienced customer service representatives standing by ready to help you!

***MPN HP 10565A
***OEM Hewlett Packard ( HP ) / Agilent
***SKU*** DP063

Read More

Tropel 9000 Laser Interferometer

This is a Tropel Model 9000 laser interferometer. It is used for checking the flatness of wafers and masks up to 5 inches in diameter. It uses a HeNe laser as a monochromatic source, and has a built-in video camera for fringe display on a Sony Black & White monitor.

The interferometer is in spectacular condition with the exception of a small scratch near the upper center of the reference prism (outside the field of view of all but the largest wafers). The wafers are held in place by a vacuum chuck and fringe spacing and direction is adjusted via three very fine setting screws located to either side and beneath the chuck holder.

The interferometer includes the following chucks:
� 2 inch vacuum chuck
� 3 inch vacuum chuck
� 4 inch vacuum chuck
� 5 inch ‘bow’ chuck

***MPN Model 9000
***OEM Tropel
***SKU*** 17698

Read More

Zygo Mark IV HDP Interferometer Mainframe

Zygo Mark IV HDP Interferometer Mainframe.

This system includes the following pieces:
– Zygo HDP Mark IV, P/N 6184-0100-01, MFG July 1987
– Zygo Keyboard, P/N 6194-0137-01
– Power cords and other cables included
***MPN Mark IV HDP
***OEM Zygo
***SKU*** 57676

Read More

Excell Laser Interferometer System 1100 components

Excell Laser Interferometer System 1100 components
1001B Laser Head Dual Frequency HeNe Zeeeman
Two 1031F Detectors
Two fiber optic cables
Two detector cables
cable with laser head
Two 1032B electronic boards
Optics are available separately at time of listing (1014A, 1012A)
power supply is not included

***MPN 1100
***OEM Excel Precision
***SKU*** 61363

Read More