Product Description
Fluke Biomedical 35080M kVp Divider – Non-Invasive X-Ray Tube Voltage Measurement
This used Fluke Biomedical 35080M kVp Divider is a specialized instrument designed for non-invasive measurement of kilovoltage peak (kVp) in X-ray systems. It provides a safe, fast measurement of kVp without endangering personnel or equipment, primarily intended for X-ray machine service and calibration .
The Model 35080M kVp Divider is an alternative to bulky, heavy high-voltage divider tanks. Its compact design fits easily into a shirt pocket, making it highly portable for field service applications .
Key Specifications
| Specification | Details |
|---|---|
| Manufacturer | Fluke Biomedical |
| Model | 35080M |
| Type | Non-invasive kVp Divider |
| Measurement Range | 50 – 150 kVp (with Wide Range Filter Pack 37617) |
| Accuracy | ± 2% of reading (exclusive of linearity, filtration, and gain effects) |
| Response Time | 150 microseconds (10-90%) |
| Permitted Tube Current | 1 mA to 3000 mA (dependent on waveform and distance) |
| Output | Analog voltage proportional to instantaneous X-ray tube voltage |
| Calibration | Internally generated signal provides calibration check |
| Battery | One 9V alkaline (Eveready 522 type), ~50 hour life |
| Dimensions | 25 mm x 130 mm x 65 mm (1″ x 5.125″ x 2.56″) |
| Weight | 180 g (6.3 oz) including battery |
| Operating Temp | 15° to 35°C |
| Storage Temp | -35° to 50°C |
| Humidity | Up to 90% relative humidity |
Key Features & Benefits
Non-Invasive Measurement:
Provides safe, non-invasive measurement of kVp without disturbing high-voltage supply cables. The kVp divider is placed on the X-ray table with the filter pack in place, and the X-ray beam is collimated to the area of the filter pack .
Analog Output:
Provides an analog output voltage proportional to the instantaneous voltage applied to the X-ray tube. When connected to a storage oscilloscope (such as the Fluke 199XRAY Medical ScopeMeter), the kV waveform may be viewed directly .
Compatibility:
Can be connected to the Model 35050AT Dosimeter/kVp Readout for digital display of kVp values .
Portable Design:
Highly portable design contrasts with bulky, heavy high-voltage divider tanks, making it ideal for field service and biomedical engineering applications .
Wide Range Filter Pack:
Includes the Wide Range Filter Pack (37617) which allows high-accuracy measurements from 50 to 150kV .
Available Filter Packs & Options
| Filter Pack | Model | Application |
|---|---|---|
| Wide Range | 37617 | Standard 50-150 kVp measurement |
| Cadmium K-Edge Mammo | 37355 | Mammographic measurements |
| Linear Mammo | 37351 | Mammographic linear measurements |
| CT Filter Pack | 33551 | CT imaging applications |
| Mobile Filter Pack Plus | 37946 | For high ripple, high frequency generators (>1kHz, >8% ripple) |
| Low Range | 38237 | Lower kVp applications |
Mobile Filter Pack Application Note
The Model 37946 Mobile Filter Pack is required when measuring mid-to-high-frequency generators (>1 kHz) with substantial kV ripple (>8%). Use this filter pack only when both conditions exist simultaneously :
-
Ripple must be greater than 8% of the kVp
-
Ripple frequency must be greater than 1 kHz
If neither condition is present, use the wide range filter pack (50 to 150k) .
Applications
-
X-Ray System Calibration: For radiographic, fluoroscopic, mammographic, CT, and dental modalities
-
Quality Assurance: Government compliance testing and JCAHO accreditation measurements
-
Preventive Maintenance: Routine verification of X-ray equipment performance
-
Troubleshooting and Repair: Diagnostic evaluation of X-ray generators
-
Installation and Setup: New equipment verification
Condition
SOLD AS IS
USED – SHOWS NORMAL HANDLING
BATTERY STATUS: [Unknown – replace before use]
FUNCTIONALITY NOT TESTED
NO OSCILLOSCOPE, DOSIMETER, OR CABLES INCLUDED (unless specified)
PICTURE MAY NOT MATCH PRODUCT
⚠ OPERATING NOTE: This instrument requires a 9V battery for operation. Before use, verify battery condition using the BAT CHK function per the user manual . The instrument should be used only by persons trained in radiation safety procedures .