Showing 81–100 of 394 results

  • HP 10715A Differential Interferometer

    $1,200.00

    HP 10715A Differential Interferometer

    HP 10715A Differential Interferometer, new in the original packing. It is one of the more elaborate interferometers using the 1.5� cube form factor. These components belong to the Hewlett-Packard Laser Interferometer Distance Measurement Apparatus. The interferometer includes a special diagonal beam-splitting window which I have not figured out � it may be some sort of phase shifting plate to turn the plane of polarization. The interferometer includes a special magnetic target disk used in the initial setup of the device. It includes two retroreflector modules and a converter window, but attached to the opposite side from the converter, is another module with a right-angle beam-splitter with two exit ports on each side, marked �A� and �B�. There appears to be a quarter-wave plate between the main interferometer body and the second beam splitter. I have no idea how the diagonal mirror is used. . .

    Slight chip on unused portion of the reference mirror.

    Again, this is new in the box. I believe this component would benefit from the use of the large leveling base (HP 10711A). The only mounting faces are the opposite sides of the main interferometer body.

    ***MPN HP 10715A
    ***OEM Hewlett Packard ( HP ) / Agilent
    ***SKU*** DP070

    Add to cart
  • HP 10702A Linear Interferometer Options

    $350.00

    HP 10702A Linear Interferometer with Options 001

    This item, while missing the original HP label, has been identified as a type 10702A Linear Interferometer. The interferometer body has been scribed with the original beam-path schematic diagram found on the original label. This is one of the �medium-sized� components in the Hewlett-Packard Laser Interferometer Distance Measurement Apparatus. The central cube is 1.5� square. On one side of the beam-splitter is a type HP 10703A Retroreflector, and on the opposite side, a type HP 10724A Plane Mirror. This interferometer is equipped with the Option 001 � a type HP 10722 Converter Window. None of the components have the original labels.

    The angle of the beam-splitter is not critically set within the cube in order to keep component prices reasonable. For precise positioning it is recommended that the beam-splitter is fixtured using a large leveling base (HP 10711A). These mounts allow for corrections in two directions. Pitch may be adjusted through several degrees about the axis of the mirror component by resetting the cradle position in the base, and yaw may be adjusted using the play in the elongated slots for securing the base. The base of the mount has an open aperture so the beam path may be directed through the base of the fixture. Beams should ONLY be deflected at right angles in each laser / detector assembly in order to avoid depolarization of the laser beams.

    These components have been removed from various fixtures. They have been classified as second quality because of the missing labels as well as the rather crudely scribed schematics. All optical surfaces are free of blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear in very fine condition, although not new. Unlike new components, no hardware is included.

    BMI Surplus, Inc. is your #1 resource for new, pre-owned, recycled, refurbished & used optics, optical tables, laser tables, vibration isolation systems, legs and bases & optical support & optical accessories. We will work with you individually to find the perfect set up for your application. Shop our Optical Tables for the most competitive optical table price. Buy online or give us a call at 781-871-8868.We have experienced customer service representatives standing by ready to help you!
    **Shipping, Handling & Freight fees are dependent on your location. We will provide a freight quote to meet your individual needs and work with you if you prefer to use your own carrier. We have 30 years of experience shipping sensitive scientific instruments & industrial equipment!

    Don’t see what you are looking for? Use our orange search box on the top right hand corner of this page to customize your search.

    ***MPN HP 10702A
    ***OEM Hewlett Packard ( HP ) / Agilent
    ***SKU*** DP068

    Add to cart
  • Hewlett Packard 10567A Beam Splitter, 1st Grade

    $195.00

    This item is an HP 10567A Dual Beam Beam-Splitter. This is a rather elaborate component in the Hewlett-Packard Laser Interferometry Dimensional Measurement System. It is intended for use with two axis stages. There is a single 45-degree diagonal mirror mounted within the block, but it is not face-centered. The mirror has three �zones� of reflectance (or transmission), and three apertures on the side of the block facing the laser source. The lowest aperture is uncoated so the entire beam passes straight through the block The central aperture is where the source laser enters the block. The substrate at that point has a 50% coating, so half of the energy is reflected to the top on the block, and the remainder passes straight through. The upper aperture (on the side facing the laser) has a 100% mirror � all the light flux is diverted at right angles.

    The outer two apertures on the side facing the laser are intended for the return beams from the interferometer bodies in each axis. The receivers may be placed on the same side of the block as the laser source. This is very useful when there are space constraints.

    These components have been removed from various fixtures. They meet our requirements for first quality used interferometer components. All optical surfaces are free of blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear only lightly used, if not new. Unlike new components, however, no hardware is included.

    ***MPN HP 10567A
    ***OEM Hewlett Packard ( HP ) / Agilent
    ***SKU*** DP064

    Add to cart
  • HP 10565A Remote Interferometer

    $450.00

    This is an HP 10565A Remote Interferometer. It is one of the major components in the Hewlett-Packard Laser Interferometer Measurement System. It is based on the larger 2� cubes, and uses a 1.4� square bolt pattern for mounting. The interferometer includes the matching retroreflector (HP 10556A). The remaining three entry / exit faces of the cube appear to have � lambda plates installed within them. I believe this is the standard configuration for the interferometer. No other reflectors (retro- or mirror) are included.
    These components have been removed from various fixtures. They meet our requirements for first quality used interferometer components. All optical surfaces are free of blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear only lightly used, if not new. Unlike new components, however, no hardware is included.
    BMI Surplus, Inc. is your #1 resource for new, pre-owned, recycled, refurbished & used optics, optical tables, laser tables, vibration isolation systems, legs and bases & optical support & optical accessories. We will work with you individually to find the perfect set up for your application. Shop our Optical Tables for the most competitive optical table price. Buy online or give us a call at 781-871-8868.We have experienced customer service representatives standing by ready to help you!

    ***MPN HP 10565A
    ***OEM Hewlett Packard ( HP ) / Agilent
    ***SKU*** DP063

    Add to cart
  • Hewlett Packard 10700A 33% Splitter

    $105.00

    This item is an HP 10700A 33% Beam Splitter. It is a basic component of the Hewlett Packard Laser Interferometry Distance Measuring Apparatus. It is one of several components based on a 1� steel cube. The cube has a beam-splitting reflector set at 45-degrees and face-centered to three adjacent faces. The mirror surface is coated. These components are useful when it is desired to have three axes tied to a single laser (each axis will require its own interferometer and detector, however). The first beam-splitter in the system would be the 33% splitter, leaving roughly 66% of the beam to travel to a second 50% beam-splitter for the other two axes. In that manner each receiver will be working at approximately the same power level.
    , 2nd Grade
    The angle of the beam-splitter is not critically set within the cube in order to keep component prices reasonable. For precise positioning it is recommended that the beam-splitter is fixtured using a small leveling base (HP 10710A). These mounts allow for corrections in two directions. Pitch may be adjusted through several degrees about the axis of the mirror component by resetting the cradle position in the base, and yaw may be adjusted using the play in the elongated slots for securing the base. The base of the mount has an open aperture so the beam path may be directed through the base of the fixture. Beams should ONLY be deflected at right angles in each laser / detector assembly in order to avoid depolarization of the laser beams. Beams can be deflected through an aperture in the base of the mount for utmost versatility.

    These components have been removed from various fixtures. They meet our requirements for second quality used interferometer components. All optical surfaces are free of serious blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear in very fine condition, although not new. Unlike new components, no hardware is included.

    ***MPN HP 10700A
    ***OEM Hewlett Packard ( HP ) / Agilent
    ***SKU*** DP058

    Add to cart
  • Hewlett Packard 10700A 33% Splitter, 1st Grade

    $105.00

    This item is an HP 10700A 33% Beam Splitter. It is a basic component of the Hewlett Packard Laser Interferometry Distance Measuring Apparatus. It is one of several components based on a 1� steel cube. The cube has a beam-splitting reflector set at 45-degrees and face-centered to three adjacent faces. The mirror surface is coated. These components are useful when it is desired to have three axes tied to a single laser (each axis will require its own interferometer and detector, however). The first beam-splitter in the system would be the 33% splitter, leaving roughly 66% of the beam to travel to a second 50% beam-splitter for the other two axes. In that manner each receiver will be working at approximately the same power level.

    The angle of the beam-splitter is not critically set within the cube in order to keep component prices reasonable. For precise positioning it is recommended that the beam-splitter is fixtured using a small leveling base (HP 10710A). These mounts allow for corrections in two directions. Pitch may be adjusted through several degrees about the axis of the mirror component by resetting the cradle position in the base, and yaw may be adjusted using the play in the elongated slots for securing the base. The base of the mount has an open aperture so the beam path may be directed through the base of the fixture. Beams should ONLY be deflected at right angles in each laser / detector assembly in order to avoid depolarization of the laser beams. Beams can be deflected through an aperture in the base of the mount for utmost versatility.

    These components have been removed from various fixtures. They meet our requirements for first quality used interferometer components. All optical surfaces are free of blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear only lightly used, if not new. Unlike new components, however, no hardware is included.

    ***MPN HP 10700A
    ***OEM Hewlett Packard ( HP ) / Agilent
    ***SKU*** DP057

    Add to cart
  • Hewlett Packard 10701A 50% Splitter

    $95.00

    This item is an HP 10701A 50% Beam Splitter. It is a basic component of the Hewlett Packard Laser Interferometry Distance Measuring Apparatus. It is one of several components based on a 1� steel cube. The cube has a beam-splitting reflector set at 45-degrees and face-centered to three adjacent faces. The mirror surface is coated. These components are useful when it is desired to have two axes tied to a single laser (each axis will require its own interferometer and detector, however).

    The angle of the beam-splitter is not critically set within the cube in order to keep component prices reasonable. For precise positioning it is recommended that the beam-splitter is fixtured using a small leveling base (HP 10710A). These mounts allow for corrections in two directions. Pitch may be adjusted through several degrees about the axis of the mirror component by resetting the cradle position in the base, and yaw may be adjusted using the play in the elongated slots for securing the base. The base of the mount has an open aperture so the beam path may be directed through the base of the fixture. Beams should ONLY be deflected at right angles in each laser / detector assembly in order to avoid depolarization of the laser beams. Beams can be deflected through an aperture in the base of the mount for utmost versatility.

    These components have been removed from various fixtures. They meet our requirements for second quality used interferometer components. All optical surfaces are free of serious blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear in very fine condition, although not new. Unlike new components, no hardware is included.

    ***MPN HP 10701A
    ***OEM Hewlett Packard ( HP ) / Agilent
    ***SKU*** DP056

    Add to cart
  • Hewlett Packard 10701A 50% Splitter,

    $90.00

    This item is an HP 10701A 50% Beam Splitter .It is a basic component of the Hewlett Packard Laser Interferometry Distance Measuring Apparatus. It is one of several components based on a 1� steel cube. The cube has a beam-splitting reflector set at 45-degrees and face-centered to three adjacent faces. The mirror surface is coated. These components are useful when it is desired to have two axes tied to a single laser (each axis will require its own interferometer and detector, however).

    The angle of the beam-splitter is not critically set within the cube in order to keep component prices reasonable. For precise positioning it is recommended that the beam-splitter is fixtured using a small leveling base (HP 10710A). These mounts allow for corrections in two directions. Pitch may be adjusted through several degrees about the axis of the mirror component by resetting the cradle position in the base, and yaw may be adjusted using the play in the elongated slots for securing the base. The base of the mount has an open aperture so the beam path may be directed through the base of the fixture. Beams should ONLY be deflected at right angles in each laser / detector assembly in order to avoid depolarization of the laser beams. Beams can be deflected through an aperture in the base of the mount for utmost versatility..
    These components have been removed from various fixtures. They meet our requirements for first quality used interferometer components. All optical surfaces are free of blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear only lightly used, if not new. Unlike new components, however, no hardware is included.

    ***MPN HP 10701A
    ***OEM Hewlett Packard ( HP ) / Agilent
    ***SKU*** DP055

    Add to cart
  • Hewlett Packard 10707A Beam Bender

    $70.00

    This item is an HP 10707A Beam Bender.It is a basic component of the Hewlett Packard Laser Interferometry Distance Measuring Apparatus. It is one of several components based on a 1� steel cube. The cube has a fully-reflecting 45-degree mirror face-centered to two adjacent faces. The mirror surface is coated…

    The angle of the mirror is not critically set within the cube in order to keep component prices reasonable. For precise positioning it is recommended that the beam bender is fixtured using a small leveling base (HP 10710A). These mounts allow for corrections in two directions. Pitch may be adjusted through several degrees about the axis of the mirror component by resetting the cradle position in the base, and yaw may be adjusted using the play in the elongated slots for securing the base. The base of the mount has an open aperture so the beam path may be directed through the base of the fixture. Beams should ONLY be deflected at right angles in each laser / detector assembly in order to avoid depolarization of the laser beams. Beams can be deflected through an aperture in the base of the mount for utmost versatility.

    These components have been removed from various fixtures. They meet our requirements for second quality used interferometer components. All optical surfaces are free of serious blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear in very fine condition, although not new. Unlike new components, no hardware is included.

    2nd Grade

    BMI Surplus, Inc. is your #1 resource for new, pre-owned, recycled, refurbished & used optics, optical tables, laser tables, vibration isolation systems, legs and bases & optical support & optical accessories. We will work with you individually to find the perfect set up for your application. Shop our Optical Tables for the most competitive optical table price. Buy online or give us a call at 781-871-8868.We have experienced customer service representatives standing by ready to help you!
    **Shipping, Handling & Freight fees are dependent on your location. We will provide a freight quote to meet your individual needs and work with you if you prefer to use your own carrier. We have 30 years of experience shipping sensitive scientific instruments & industrial equipment!
    ***MPN HP 10707A
    ***OEM Hewlett Packard ( HP ) / Agilent
    ***SKU*** DP053

    Add to cart
  • Hewlett Packard 10707A Beam Bender, 1st Grade

    $90.00

    This item is an HP 10707A Beam Bender.It is a basic component of the Hewlett Packard Laser Interferometry Distance Measuring Apparatus. It is one of several components based on a 1� steel cube. The cube has a fully-reflecting 45-degree mirror face-centered to two adjacent faces. The mirror surface is coated.

    The angle of the mirror is not critically set within the cube in order to keep component prices reasonable. For precise positioning it is recommended that the beam bender is fixtured using a small leveling base (HP 10710A). These mounts allow for corrections in two directions. Pitch may be adjusted through several degrees about the axis of the mirror component by resetting the cradle position in the base, and yaw may be adjusted using the play in the elongated slots for securing the base. The base of the mount has an open aperture so the beam path may be directed through the base of the fixture. Beams should ONLY be deflected at right angles in each laser / detector assembly in order to avoid depolarization of the laser beams. Beams can be deflected through an aperture in the base of the mount for utmost versatility.

    These components have been removed from various fixtures. They meet our requirements for first quality used interferometer components. All optical surfaces are free of blemishes and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear only lightly used, if not new. Unlike new components, however, no hardware is included.

    ***MPN HP 10707A
    ***OEM Hewlett Packard ( HP ) / Agilent
    ***SKU*** DP052

    Add to cart
  • Hewlett Packard 10710A Leveling Mount, 1st Grade

    $40.00

    This item is a Hewlett Packard HP 10710A Small Leveling Mount. It is used with the smaller reflective components in their Laser Interferometry Distance Measuring Apparatus. The mounts allow for corrections in two directions. Pitch may be adjusted through several degrees about the axis of the mirror component by resetting the cradle position in the base, and yaw may be adjusted using the play in the elongated slots for securing the base. The base of the mount has an open aperture so the beam path may be directed through the base of the fixture.

    Dimensions of the base are as follows..

    Height = 0.5�

    Width = 1.1�

    Length = 1.85�

    Through-bore in base = 0.5�.

    These components have been removed from various fixtures. They meet our requirements for first quality used interferometer components. All mechanical adjustments work smoothly and there are no gouges or distortions in any of the parts that would in any way impede accuracy of measurements. Cosmetically these components appear only lightly used, if not new. Unlike new mounts, however, no hardware is included other than the two screws used to secure the cradle to the base.

    Location W7-A

    Photo set 483
    ***MPN 10710A
    ***OEM Hewlett Packard ( HP ) / Agilent
    ***SKU*** DP050

    Add to cart
  • Insp L Objective from Small Nikon Profile

    $20.00

    This is a specialized objective lens taken from a modest-sized Nikon Profile projector. It is engraved merely ‘Insp. L.’ – no magnification or any other marks on the lens. The projector was woefully incomplete and was parted out some time ago.

    Cosmetic condition of the barrel is very good – however the lens itself does suffer from numerous fine scratches from careless cleaning (last photo shows them much more pronounced than they actually are – the wonders of digital photography). The objective thread is 28.1 mm in diameter – rather odd. . . � We are also offering the other objectives from this projector as well as the original turret. Please check our other listings.

    Location MB 27

    Photo set 243
    ***MPN
    ***OEM Nikon
    ***SKU*** 3431

    Add to cart
  • Tropel 9000 Laser Interferometer

    Call 781-871-8868 for Price

    This is a Tropel Model 9000 laser interferometer. It is used for checking the flatness of wafers and masks up to 5 inches in diameter. It uses a HeNe laser as a monochromatic source, and has a built-in video camera for fringe display on a Sony Black & White monitor.

    The interferometer is in spectacular condition with the exception of a small scratch near the upper center of the reference prism (outside the field of view of all but the largest wafers). The wafers are held in place by a vacuum chuck and fringe spacing and direction is adjusted via three very fine setting screws located to either side and beneath the chuck holder.

    The interferometer includes the following chucks:
    � 2 inch vacuum chuck
    � 3 inch vacuum chuck
    � 4 inch vacuum chuck
    � 5 inch ‘bow’ chuck

    ***MPN Model 9000
    ***OEM Tropel
    ***SKU*** 17698

    Read more
  • BRUKER EQUINOX 55 SPECTROMETER INFRARED FOURNIER

    $1,000.00

    BRUKER EQUINOX 55 SPECTROMETER INFRARED FOURNIER
    ***MPN BRUKER EQUINOX 55
    ***OEM
    *** 64023***

    Add to cart
  • Brunson 88 Tilt Mounting Base

    $900.00

    The Brunson 88 Tilting Base is used for holding optical tooling telescopes and micro-adjusts left and right with socket-head screws. This accomodates all standard alignment telescopes and collimators with 2 1/4″ barrels and mounts by means of a standard 3 1/2″-8 base.
    ***MPN 88
    ***OEM Brunson
    ***SKU*** 63123

    Add to cart
  • Knight Tool Theodolite Positioner / Tilting Rotary

    $1,900.00

    This unit appears to be a theodolite positioner. This unit weighs 96 Lbs.
    This item is in good cosmetic condition.

    ***SKU*** 903

    Add to cart
  • Jodon Engineering Beam Expander BET-50

    $400.00

    Jodon Engineering Beam Expander BET-50

    50mm Aperture

    ***MPN BET-50
    ***OEM Jodon
    ***SKU*** 62561

    Add to cart
  • Gaertner Scientific Microscope with 14x Objective 80mm

    $385.00

    Microscope with 14x Objective
    Holder is Included
    Geathner Scientific
    ***MPN
    ***OEM Gaertner Scientific
    ***SKU*** 62222

    Add to cart
  • Burleigh Interferometer Head in Kinematic Mount

    Call 781-871-8868 for Price

    Burleigh Interferometer Head in Kinematic Mount.
    ***MPN
    ***OEM Burleigh
    ***SKU*** 62102

    Read more
  • Wild Heerbrugg T2 Theodolite

    $1,300.00

    Wild Heerbrugg T2 Theodolite.
    ***MPN T2
    ***OEM Wild Heerbrugg
    ***SKU*** 62025

    Add to cart